Drainage runs
| Run | Length (m) | Fall (1 in) | Pipe | Type | WCs | Fall (m) |
|---|
Fall profile
Level schedule
| Run | Chainage from | Chainage to | Start level | End level | Fall |
|---|
Minimum fall, at a glance
| Pipe diameter | Min fall - foul | Min fall - surface water |
|---|
| Run | Length (m) | Fall (1 in) | Pipe | Type | WCs | Fall (m) |
|---|
| Run | Chainage from | Chainage to | Start level | End level | Fall |
|---|
| Pipe diameter | Min fall - foul | Min fall - surface water |
|---|
Work out falls and invert levels for a drainage run. Enter a start invert level, then each run's length, fall as 1 in N, pipe size, foul or surface water, and the WCs a foul run serves. You get the fall per run, a level schedule chained run to run, a to-scale fall profile, and a flag on any run flatter than its recommended minimum.
It is free, works in your browser with no sign-up, and there is a free Windows app too.
A new foul drain starts at an invert of 98.450m. Run MH1-MH2 is 15m of 100mm pipe at 1 in 40 serving 1 WC, then MH2-MH3 is 24m of 150mm pipe at 1 in 60 serving 3 WCs.
With 1 WC the 100mm run's minimum is 1 in 80, and with fewer than 5 WCs the 150mm run's is 1 in 60, so neither is flagged as shallow. The Levels tab lists chainages and inverts to three decimals for setting out. Treat the result as an estimate - building control or your drainage designer signs off the final falls.
A 1 in 40 fall drops 1m for every 40m of pipe, which is 25mm per metre run (1000 / 40). Over a 10m run that is 250mm of fall.
Divide 1000mm by the ratio: 1 in 60 is about 16.7mm per metre and 1 in 80 is 12.5mm per metre. The bigger the second number, the flatter the pipe.
Approved Document H allows a 100mm foul drain at 1 in 80 where it serves at least one WC; the calculator applies that when you enter one or more WCs on the run, and uses 1 in 40 when it serves none. Anything flatter than the minimum is flagged as shallow.
Start from a known invert level, work out each run's fall as length divided by the ratio, and subtract it to get the invert at the next manhole or chamber. That next invert becomes the start level for the following run, which is how the calculator builds its level schedule.
Divide 100 by the ratio, so 1 in 40 is 2.5%, 1 in 60 is about 1.67% and 1 in 80 is 1.25%. To go the other way, divide 100 by the percentage to get the 1 in N figure.
Yes - set each run to foul or surface water and choose a 100, 150, 225 or 300mm pipe, and the calculator checks it against its minimum for that size, type and, for foul runs, the WCs served (a 150mm foul run drops to 1 in 150 at five or more WCs). It works on below-ground drain runs in metres and does not size pipes for flow, so surface water drains of 225mm and above still need a proper hydraulic design.